12. TROUBLESHOOTING
Symptom Cause Possible Solution
Machine will not turn on:
a. Power switch is in "0"
(Off) position
b. Tripped circuit breaker.
c. Blown main power fuse.
a. Put the power switch to
the "I" (On) position
b. Reset the circuit breaker.
c. Replace the fuse.
There is power, but the
rollers are not turning after
the "RUN" button is pressed:
a. Safety cover is not closed.
b. Front table is not installed
correctly.
c. Blown motor fuse.
a. Close the safety cover to
active the safety switch.
b. Properly install the Front
table so that the micro
switch is activated.
c. Replace the motor fuse.
The unit is not heating up
a. The machine is in "COLD"
mode.
b. Set temperature is lower
than the room
temperature.
a. Switch to "HOT" mode.
b. Raise the temperature
according to the
recommended film
temperature.
Curled lamination:
a. Upward curl.
b. Downward curl.
a. Loosen the top roll film
tension.
b. Loosen the bottom roll
film tension.
Unclear lamination:
The hot roller temperatures
are too low and/or lamination
speed is too fast.
Raise the roller
temperatures and/or lower
the lamination speed.